Troubleshooting the Drive Using the OIM

7-9

7.7

Alarm and Fault Names Cross-Referenced to Front
Panel Keypad/Display Codes

The following tables list the fault and alarm messages that can occur on the OIM. They
are cross-referenced to the fault and alarm messages as listed in chapter 5 of the
software I/M.

Table 7.3 – List of Alarms Cross-Referenced to Front Panel Keypad/Display Alarm Codes

OIM Alarm Name

Front Panel

Keypad/Display

Code

Software I/M

Alarm Description

ANALOG IN SIGNAL
LOSS

1

1

Only supported with GV3000/SE drive version 6.03 and later.

AIn

Analog input signal loss

HIGH DC BUS VOLTAGE

2

2

Only supported with GV3000/SE drive versions 6.0 and later.

HIdc

High DC bus voltage

LOW AC INPUT LINE

LIL

Low AC input line

VECTOR SELF-TUNING
ACTIVE

S-Ac

Vector self-tuning active

VECTOR SELF-TUNING
ENABLED

S-En

Vector self-tuning enabled

V/HZ IDENT PROCEDURE
ACTIVE

I-Ac

V/Hz identification procedure
active

V/HZ IDENT PROCEDURE
ENABLED

I-En

V/Hz identification procedure
enabled

Table 7.4 – List of Fault Codes Cross-Referenced to Front Panel Keypad/Display Fault Codes

OIM Fault Name

Front Panel

Keypad/Display

Code

Software I/M

Fault Description

ANALOG IN SIGNAL
LOSS

1

AIn

Analog input signal loss

ASYMMETRICAL BUS
CHARGE

UbS

Asymmetrical bus charge

COMM LOSS BETWEEN
REGULATOR/PC

SrL

Communication loss between
regulator/PC

DC BUS CHARGING
BYPASS CONTACTOR

bYC

DC bus charging bypass
contactor

DEFAULT PARAMETER
RESTORE

CHS

Default parameter restore
(checksum error)

DRIVE
OVERTEMPERATURE

OH

Drive overtemperature

DRIVE POWER
ELECTRONIC OVERLOAD

PUo

Drive power electronic overload

ENCODER LOSS

EL

Encoder loss

FUNCTION LOSS

FL

Function loss

Advertising