Electrical pretest, continued, Fault isolation procedures, Step b procedure condition action – Bendix Commercial Vehicle Systems VORAD EVT-300 TROUBLESHOOTING User Manual

Page 14: Vorad, System. go to step a

Advertising
background image

Fault Isolation Procedures

2-3

Electrical Pretest, continued

Step B

Procedure

Condition

Action

1. Key off.

2. Disconnect negative (-) battery

cable.

3. Disconnect 32-way connector

from Central Processing Unit.

4. Measure resistance

between 32-way
connector pin C-2 and
ground.

If resistance is 0 to .5 ohms

If resistance is outside of
range

Go to Step C.

Repair ground path for Bendix

VORAD

®

system. Go to Step A.