Fault isolation procedures code 23 (sid 3, fmi 2) – Bendix Commercial Vehicle Systems VORAD EVT-300 TROUBLESHOOTING User Manual

Page 71

Advertising
background image

Fault Isolation Procedures

Code 23

(SID 3, FMI 2)

2-60

Code 23 (SID 3, FMI 2) Brake Input Error, continued

Step D

Procedure

Condition

Action

Step E

Procedure

Condition

Action

1. Key off.

2. Depress brake pedal.

3. Measure voltage between

Central Processing Unit
pins C9 and C2.

1. Key off.

2. Reconnect Central Processing Unit

32-way connector.

3. Connect a PC-based or Hand-held

Diagnostic Tool.

4. Key on.

5. Perform brake test to

verify correct signal is
received when brake
pedal is depressed.

If voltage is within 1 volt of
battery voltage

If voltage is outside of range

If correct signal is received

If correct signal is not
received

Replace Central Processing
Unit
. Go to Step V.

Repair OEM wiring harness as
necessary. Go to Step V.

Replace Central Processing
Unit
. Go to Step V.

Repair OEM wiring harness.
J-1587 or J-1939 data link
may not be connected to the
Bendix

VORAD

®

system.

Go to Step V.