Fault isolation procedures – Bendix Commercial Vehicle Systems VORAD EVT-300 TROUBLESHOOTING User Manual

Page 76

Advertising
background image

Fault Isolation Procedures

2-65

Code 24 (SID 6, FMI 2) Speed Input Error, continued

Step C

Procedure

Condition

Action

Step D

Procedure

Condition

Action

1. Measure resistance

between Central
Processing Unit 32-way
connector pin C10 and
ground.

1. Disconnect VORAD harness from

speed source.

2. Measure resistance

between speed sensor
pins A and B.

If resistance is more than
10K ohms or open circuit
[OL]

If resistance is less than 10K
ohms

If resistance is 2 to 4K ohms

If resistance is outside of
range

Replace Central Processing
Unit.
Go to Step V.

Go to Step D.

Go to Step E.

Replace speed sensor.
Go to Step V.

OHMS

GROUND

V

A

COM

1

C

D

2

3

4

5

6

7

8

9

10

11

12

13

14

16

15

OHMS

V

A

COM

A

B