Power-up sequence test – Bendix Commercial Vehicle Systems VORAD EVT-300 TROUBLESHOOTING User Manual

Page 17

Advertising
background image

Fault Isolation Procedures

P

ow
er

-Up Sequence T

est

2-6

Power-Up Sequence Test

Step A

Procedure

Condition

Action

Step B

Procedure

Condition

Action

1. Before performing this test, the

Electrical Pretest must pass.

2. Key on.

3. Observe the Driver

Display Unit.

1. Key on.

2. Disconnect the 4-way connector

from the Driver Display Unit.

Note: Not applicable for

Freightliner IDI.

3. Measure voltage

between pins C and D
on the Driver Display
Unit 4-way connector.

If lights turn on the go off
after approximately 15
seconds

Note: Not applicable for

Freightliner IDI

If lights fail to turn on

If lights turn on and stay on

If voltage is between 7.0
and 7.5 volts

If voltage is outside of
range

Test complete.

Go to Step B.

Go to Step C.

Go to Step C.

Go to Step G.

VOLT

V

A

COM

D

C

B

A