Code 24 (sid 6, fmi 2) speed input error, Fault isolation procedures code 24 (sid 6, fmi 2) – Bendix Commercial Vehicle Systems VORAD EVT-300 TROUBLESHOOTING User Manual

Page 75

Advertising
background image

Fault Isolation Procedures

Code 24

(SID 6, FMI 2)

2-64

Code 24 (SID 6, FMI 2) Speed Input Error

Step A

Procedure

Condition

Action

Step B

Procedure

Condition

Action

1. Using a PC-based or

Hand-held Diagnostic
Tool verify vehicle speed
confi guration.

1. Key off.

2. Disconnect Central Processing

Unit 32-way connector.

3. Measure resistance

between Central
Processing Unit pins C10
and C11.

If confi guration is set to Discrete

If vehicle uses J-1939 or
J-1587 confi guration

Note: If 32-way connector does not

have pins in C10 and C11,
recheck vehicle confi guration
for speed source. This test is
used for discrete installations
only.

If resistance is 2 to 4K ohms

If resistance is outside of range

Go to Step B.

Repair OEM wiring harness.
J-1587 or J-1939 data link
may not be connected to the
Bendix

VORAD

®

system.

Go to Step V.

Go to Step C.

Go to Step D.

V

A

COM

1
2
3

4

5

6

7

8

9

10

11

12

13

14

16

15

Advertising