Fault isolation procedures, Step e procedure condition action – Bendix Commercial Vehicle Systems VORAD EVT-300 TROUBLESHOOTING User Manual

Page 58

Advertising
background image

Fault Isolation Procedures

2-47

Code 16 (SID 11, FMI 2) Left Side Sensor, continued

Step E

Procedure

Condition

Action

1. Key off.

2. Disconnect Central Processing

Unit 32-way connector.

3. Measure resistance between:

• 32-way pin D14

and 3-way pin A.

• 32-way pin D14

and ground.

If resistance between D14
and pin A is 0 to 0.3 ohms
and if resistance between
pin D14 and ground is more
than 10K ohms or open
circuit [OL]

If resistance is out of range

Replace Central Processing
Unit.
Go to Step V.

Repair OEM wiring harness
between Left Side Sensor and
Central Processing Unit.
Go to Step V.