Fault isolation procedures, Step c procedure condition action – Bendix Commercial Vehicle Systems VORAD EVT-300 TROUBLESHOOTING User Manual

Page 34

Advertising
background image

Fault Isolation Procedures

2-23

Code 13, 34 (SID 9, FMI 2, 4, 5, 12) Driver Display Unit, continued

Step C

Procedure

Condition

Action

1. Key off.

2. Disconnect Central Processing

Unit 32-way connector.

3. Measure resistance between:

Central Processing
Unit 32-way
connector pin D3
and Driver Display
4-way connector
pin D.

Central Processing
Unit 32-way
connector pin D3
and ground.

If resistance between D3 and
D is 0 to .3 ohms and if
resistance between pin D3
and ground is more than 10K
ohms or open circuit [OL]

If any of the above conditions
are not met

Go to Step D.

Repair OEM wiring harness
between Driver Display Unit
and Central Processing Unit.
Go to Step V.

1

C

D

2

3

4

5

6

7

8

9

10

11

12

13

14

16

15

1

C

D

2

3

4

5

6

7

8

9

10

11

12

13

14

16

15

D

C

B

A

OHMS

V

A

COM

OHMS

GROUND

V

A

COM