Fault isolation procedures, Step c procedure condition action – Bendix Commercial Vehicle Systems VORAD EVT-300 TROUBLESHOOTING User Manual
Page 50
Advertising
Fault Isolation Procedures
2-39
Code 15 (SID 10, FMI 2) Right Side Sensor, continued
Step C
Procedure
Condition
Action
1. Key off.
2. Disconnect Central Processing
Unit 32-way connector.
3. Measure resistance between:
• 32-way pin C12
and 3-way pin C.
• 32-way pin C12
and ground.
If resistance between C12
and pin C is 0 to 0.3 ohms
and if resistance between
pin C12 and ground is more
than 10K ohms or open
circuit [OL]
If resistance is outside
of range
Go to Step D.
Repair OEM wiring harness
between Right Side Sensor and
Central Processing Unit.
Go to Step V.