B&G H2000 Pilot *DISCONTINUED* User Manual

Page 114

Advertising
background image

HB-0844-04

4-18

8-BUTTON NMEA FULL FUNCTION

DISPLAY INSTALLATION SHEET







INSTALLATION NOTES

An NMEA FFD can be connected at any point on the system network. Typically an NMEA FFD is mounted close
to the NMEA device; for example at the chart table next to the GPS, thus minimising the NMEA cable routes.

NMEA FFD's can be used in combination with all other display types; that is standard FFD's, Halcyon displays,
20/20 and Pilot displays.


SCREENED CABLES

Shielded NMEA cables are supplied to provide protection against unwanted emissions (EMC) and must be
connected in accordance with these instructions.

NMEA cable shields must be connected at the TRANSMITTING end.

The NMEA output cable shield should be connected to the other cable shields in the junction box supplied.


NETWORK TERMINATION

If the NMEA FFD is the last unit on the system network a network terminator MUST be fitted across the network
data wires, that is between the green and white wires. Only two network terminators are required per system.

NMEA FFD CABLE

FUNCTION

FFD CABLE

COLOUR

SYSTEM

NETWORK

NMEA
INPUT

NMEA

OUTPUT

REMOTE

BUTTON

Network Data -ve

Green

Green

Network Data +ve

White

White

Network Cable Shield

Shield

Shield

Shield

Ground

Black

Black

Blue

Blue

Supply +ve

Red

Red

NMEA Input Signal

Brown

Red

NMEA Input Return

Blue

Blue

NMEA Output Signal

Violet

Red

Remote Control Button

Yellow

Red