1. When calibration value 1 is changed to select a desired input sensor, the

linear value is no longer updated and a constant value is displayed until the
page key is pressed.

2. Extra functions selected, and then removed, remain in the display menu

but with no data shown until the system is switched off and then back on
again.

3. Linear functions will always be shown if selected by CAL VAL 4 on linear

5. They will show no data if the CAL VAL 1 setting is configured to 1 or 2.


5.9.4

Expansion Processor Wiring


The Expansion Processor is connected to the system Fastnet for power and
data requirements.

TERMINAL

FUNCTION

WIRE COLOUR

1

Meter 5 SIN

Green

2

Meter 5 COS

Blue

3

Meter 6 SIN

Red

4

Meter 6 COS

Violet

5

Meter 7 SIN

Red

6

Meter 7 COS

Violet

7

Meter 8 SIN

Green

8

Meter 8 COS

Blue

9

Meter Lighting

Yellow

10

Meter Common

Orange

11

Meter Ground

Black

12

N/C

13

N/C

14

Network Data -ve

Green

15

Network Data +ve

White

16

Network Screen

Screen

17

Battery Supply
Ground

Black

18

Battery Supply 12V

Red

19

Battery Volts Sense

Link to 18

20

N/C

21

Ground

Blue

22

Sensor Supply
+6.5V

Red