HB-0844-04

3-8

(12) If a third run is required, press Scroll Down to STRT RUN
then repeat from step (8).

The yacht's log is now calibrated and the new calibration value is stored
permanently in the computer’s memory.

Note
“ERR” will be displayed if the system encountered a problem during the
calibration run. For example, if the calibration distance was too short.

3.2.6

Manual Calibration

The calibration values can be adjusted directly as shown in 'Examples of
Calibration’ included in Part 2 - Operating Information.

3.2.7

Boat Calibration (ref. to a Known Value)

The following enhancement is only available when the Hydra Depth Unit is
used in conjunction with the Hydra 2000 FFD Display version later than 5C.

To calibrate the Boat Speed by reference to a known value, e.g., another
boat with an accurately calibrated log proceed as follows:

Select BOAT SPD KT on the upper half of the FFD Display.

(1) Press Scroll Down until the lower text shows CALBRATE
flashing.

(2) Press Enter, the lower text now shows AUTO CAL flashing.

(3) Press Scroll Down until the lower text shows REF CAL
flashing.

(4) Press Enter, the lower text now shows REF CAL along with
current Boat Speed.

(5) Press Enter, the lower text now shows REF CAL flashing and
by use of the Scroll Up/Down the reference speed may be
adjusted.

(6) Press Enter, the new speed value is accepted and the upper
display will show the re-calibrated boat speed.