B&G H2000 Pilot *DISCONTINUED* User Manual

Page 125

Advertising
background image

HB-0844-04

5-8

5.3.2

Analogue Indicator Configuration


If meters other than the defaults are chosen then it is necessary to
reconfigure the outputs. This is done from any FFD as follows:

(1) Power up the system from any FFD while holding down the
Enter Key, DIAGNOST appears.

(2) Press Scroll Up, CNFG SYS appears, press Enter to select
this option. Now press Enter again to select the METERS option.

(3) With OPTIONS flashing, press Enter, METER 1 appears, the
Scroll Up Key is now used to scroll through the meter outputs.
(Refer to the installation sheet to determine the meter options and
their respective meter drives).

(4) With the appropriate meter output flashing in the top display,
press Enter to reveal the current option assigned to that meter.
Pressing Scroll Up at this stage, and then Enter again, will reveal
the METER 2 option. Repeating this process will reveal the METER
3 and METER 4 options as required.

(5) Press Enter, the lower text will flash. Use Scroll Down to scroll
through the options until the appropriate one (e.g. DEPTH) is shown.
Pressing Enter will select that option, and the meter output will be
configured to drive a DEPTH meter.

(6) Press Page to return to normal operation.

Note
It is possible to configure more than one meter drive to the same meter
option (e.g. BOAT SPD on METER 1 and METER 2).