3-7

3.2.5

Log AUTO CAL Procedure

(1) Select Boat Speed on the display.

(2) If BOAT SPD is in Upper Display, press and hold Scroll Down
to select CALBRATE. If BOAT SPD is in Lower Display, use Scroll
Up
to select CALBRATE.

(3) Press Enter, display shows the current Boat Speed reading
with AUTO CAL flashing.

(4) Press Enter, display shows the current Boat Speed reading
with SINGLE flashing.

(5) Press Enter twice, display shows the default setting for the
actual calibration distance for each run along the given course.

(6) Press Enter, CAL DIST will flash. The Scroll Up and Scroll
Down
Keys can now be used to select the appropriate measured
distance. Press Enter to accept new distance. The system is now
ready to start the first calibration run.

(7) Press Scroll Down, STRT RUN appears, flashing.

(8) When crossing the first transit mark of the run, press Enter.
The display now shows the current Boat Speed reading with STOP
RUN flashing.

(9) When crossing the transit mark at the end of the run press
Enter. The display shows the current Boat Speed reading with END
CAL flashing.

(10) Press Scroll Down to select STRT RUN again then repeat
steps (8) and (9).

(11) If only two runs are required, press Enter to end calibration.
The Lower Display will now show the new calibration value that has
automatically been calculated by the Main Processor. This should
be recorded on the chart provided.