B&G H2000 Pilot *DISCONTINUED* User Manual

Page 35

Advertising
background image

HB-0844-04

2-16

2.6.2

Calibration Adjustment - Depth

(1) Using the Scroll Up or Scroll Down Keys select the upper or
lower display as required.

(2) If DEPTH is shown in the upper display, press and hold the
Scroll Down Key to select CALBRATE from the menu. If DEPTH
is in the lower display use Scroll Up.

(3) Press Enter and the display shows DATUM which flashes.

(4) Press Enter again, DATUM stops flashing and the current
datum value is displayed.

(5) Press Enter and the DATUM value flashes.

(6) Use the Scroll Up or Scroll Down Keys to set the new
DATUM value.

Note:

If DATUM is referenced to the water line, the value is positive.
If DATUM is referenced to the keel line, the value is negative
and this is indicated by a minus sign before the left digit.

(7) Press Enter to input the new DATUM value into the system.

(8) Press Page to return to the normal display.

2.6.3

Calibration Adjustment - Wind Angle

(1) Select APP W/A.

(2) If APP W/A is on lower display press Scroll Up and scroll to
CALBRATE which flashes. If APP W/A is on upper display, press
Scroll Down and scroll to CALBRATE.

(3) Press Enter twice and the current alignment value will be
shown.

(4) Press Enter and the current offset angle will flash. Use Scroll
Up
or Scroll Down to set the new value.

(5) Press Enter to accept the new value.

(6) Press Page to return to the normal display.