1 front panel cooling area – Kontron NSW1U IP Network Server User Manual

Page 23

Advertising
background image

Kontron IP Network Server NSW1U

December 2009

Product Guide, rev. 1.4

23

Kontron IP Network Server NSW1U Features—NSW1U Network Server

2.11.1

Front Panel Cooling Area

The left one-fourth of the EFP front panel board and the portion of the PDB in this area are cooled by

40 Ч 40 Ч 56 mm dual-rotor fans internal to the PSUs. One PSU is sufficient to cool this portion of the

front panel board area and two PSUs provide cooling redundancy for this area.

PSU fans draw air in through the bezel from the front of the system and from vents in the left front

side of the chassis over this portion of the front panel board and PDB, through and exhausting out the

rear of the PSUs. The left wall of the PCI fan air duct and the PSU guide wall provide an air flow

barrier between the front panel board cooling area and the PCI cooling area

Figure 11.

Cooling Areas

AF000830

Front Panel

Board Area

Airflow

PCI Area
Airflow

CPU-Memory-

HDD Area

Airflow