Server Component Replacements—NSW1U Network Server

3. Connect the fan cables to the correct fan connectors as labeled on the Ethernet front panel board.
4. Check to be sure that none of the bumpers are caught on the bracket. (

Figure 51

, “A”)

5.2.3

Removing the PCI Fan

1. Unplug the PCI fan power cable from the EFP board.
2. Remove the fan from the bracket.

5.2.4

Installing the PCI Fan

1. Route the power cable to the front of the bracket before seating the fan in the bracket. Be sure

the air flow is toward the rear of the chassis.