90

7.6

BIOS Error Messages

When a recoverable error occurs during the POST, the BIOS displays an error message describing the

problem.

CPU Fault

Identify processor

failure

front center of

server board

(DS4J1)

Amber

On = Fault

5v Standby

Identify 5v standby

power on state

Front left board

Amber

On = 5v standby power on

Power LED

Identify the power

state of the system

Control Panel

Green

Off = Power is off (off or S5)
On = Power on or S0)
Slow Blink = Low power

state (S1 – S3)

Table 9.

BIOS Error Messages (Sheet 1 of 2)

Error Message

Explanation

GA20 Error

An error occurred with Gate A20 when switching to protected

mode during the memory test.

Pri Master HDD Error

Pri Slave HDD Error

Sec Master HDD Error

Sec Slave HDD Error

Could not read sector from corresponding drive.

Pri Master Drive - ATAPI Incompatible Pri

Slave Drive - ATAPI Incompatible Sec

Master Drive - ATAPI Incompatible Sec

Slave Drive - ATAPI Incompatible

Corresponding drive is not an ATAPI (Advanced Technology

Attachment Packet Interface) device. Run Setup to make sure

device is selected correctly.

A: Drive Error

No response from diskette drive.

CMOS Battery Low

The battery may be losing power. Replace the battery soon.

CMOS Display Type Wrong

The display type is different from what has been stored in CMOS.

Check Setup to make sure type is correct.

CMOS Checksum Bad

The CMOS checksum is incorrect. CMOS memory may have been

corrupted. Run Setup to reset values.

CMOS Settings Wrong

CMOS values are not the same as the last boot. Either these values

have been corrupted or the battery has failed.

CMOS Date/Time Not Set

The time and/or date values stored in CMOS are invalid. Run Setup

to set correct values.

DMA Error

Error during read/write test of DMA (Direct Memory Access)

controller.

FDC Failure

Error occurred trying to access diskette drive controller.

HDC Failure

Error occurred trying to access hard disk controller.

Checking NVRAM.....

NVRAM (Non-Volatile Random Access Memory) is being checked to

see if it is valid.

Update OK!

NVRAM was invalid and has been updated.

Updated Failed

NVRAM was invalid but was unable to be updated.

Keyboard Error

Error in the keyboard connection. Make sure keyboard is

connected properly.

KB/Interface Error

Keyboard interface test failed.

Table 8.

LED Definitions

LED Name

Function

Location

Color

Notes