2 removing dimms, 4 installing or replacing the processor, Removing dimms – Kontron NSW1U IP Network Server User Manual

Page 35: Installing or replacing the processor, Figure 16

Advertising
background image

Kontron IP Network Server NSW1U

December 2009

Product Guide, rev. 1.4

35

Server Installations and Upgrades—NSW1U Network Server

3.3.3.2

Removing DIMMs

To remove a DIMM, follow these steps:

1. Power down the server system and unplug all peripheral devices and the power cord.
2. Remove the chassis cover. For instructions, see

Section 3.2.1, “Removing the Chassis Cover” on

page 25

.

3. Remove the air duct. For instructions, see

Section 3.2.5, “Removing the Processor Air Duct” on

page 27

.

4. Locate the DIMM(s) on the server board and select the one(s) you want to remove. See

Figure 16

.

5. Open the DIMM socket levers.
6. Holding the DIMM by the edges, lift it away from the socket, and store it in an anti-static package.
7. Replace the chassis cover if you have completed all work inside of the server.

3.3.4

Installing or Replacing the Processor

Note:

Use the instructions provided below to replace a processor instead of using the

instructions that came with the processor.

Caution:

The processor must be appropriate: You could damage the server board if you install a

processor that is inappropriate for your server. For a list of compatible processors for

the NSW1U Network Server, go to

http://us.kontron.com/products/

systems+and+platforms/communication+rackmount+servers/ip+network+servers/

ip+network+server+nsw1u.html

. Click on Downloads, and then click on Ordering

Guide.

Figure 16.

Installing Memory DIMMs

Channel 1

Channel 0

DIMM A1

DIMM A2

DIMM B3

DIMM B2

DIMM A3

DIMM B1

E

A

C

D

B

AF000775

Advertising