12 MSI-7300 Operator’s Manual

2.0 Operation

2.1 Power

To turn on the Power

1. Press

POWER

.

• The LCD will show all segments for a display test.
• The software version number will display.

The Dyna-Link 2 is ready for use.

2.2 Zero

Takes out small deviations in zero when the Dyna-Link 2 is unloaded. See Section 3.6

for zeroing (Taring) package or pallet weights.

Note

Note

The tension reading must be stable within the motion window for the
zero function to work.

1. Press

ZERO

. The display reads 0 (or 0.0 or 0.00, etc).

The backup memory stores the zero reading, and can restore it even if
power fails.

Zero - Rules for Use:

• Works in

GROSS

mode or

NET

mode. Zeroing while in

NET

mode will zero

the gross tension causing the display to show the negative tare value.

• The unit must be stable within the motion window, it will not zero until the

stable annunciator is on.

• The unit will “remember” that it has a zero request for two seconds. If motion

clears in that time, it will zero.

• The unit will accept a zero setting over the full range of the Dyna-Link. Zero

settings above 4% of full Dyna-Link will subtract from the overall capacity.

For example, if you zero out 100 lb on a 1000 lb Dyna-Link, the overall

capacity will reduce to 900 lb plus the allowed over-range amount.