User Key Functions (F1and F2) 13

3.0 User Key Functions (F1and F2)

There are optional functions that can be programmed for the function keys (

F1

and

F2

) on the front panel, as well as on the RF remote display. See Section 4.2 for setup

instructions.

Note

The functions PRINT (F3), and TARE are available full time on the RF
remote display.

3.1

OFF

No

USER

key function assigned. The F-Key is disabled.

3.2

TEST

The

TEST

function provides an LCD test that lights all LCD segments and the LED at

once and then counts from 00000 to 99999. Other internal tests are performed and if

any test fails, an error code will display. See Section 7.2 for a description of all error

codes.

3.3

TOTAL

Note

The Total Mode must be programmed from the setup menus before
the USER key will function. See Section 4.5.

For accumulation of multiple weighments. The accumulator always uses the

displayed weight, so GROSS and NET readings can be added into the same

TOTAL

.

There are four modes of totalizing: manual and three auto modes.
The manual mode requires the

TOTAL

key be pressed with the tension on the unit. The

tension will then be added to the previously accumulated value. This assures that a

weight on the scale is only added to the total once. Both the manual and three auto

total modes require that the tension on the Dyna-Link return below 0.5% (relative to

full scale) of GROSS ZERO or NET ZERO before the next weighment can be added.

Applied weight must be ≥1% of full scale above GROSS ZERO or NET ZERO

before it can be totaled.

3.3.1

MANUAL TOTAL

The

Fx-TOTAL

key under the MANUAL TOTAL mode functions in this manner:

1. With the tension at more than 1% of capacity, push the

Fx-TOTAL

key to add the

current tension to the TOTAL weight. The

Fx

LED blinks to indicate the tension

value was accepted. The TOTAL LCD annunciator and the total weight is

displayed for about five seconds, then the number of samples is displayed for

about two seconds.

2. Remove the weight, when the tension is less than 1% of capacity, place next

load to be accumulated on the unit.

3. Repeat until all loads to be accumulated have been added to the total.
4. To view the total weight accumulated, push the

Fx-TOTAL

key with the tension

at less than 1% of capacity (no weight on unit), the total weight will display for

five seconds (view total) without changing the total value. The TOTAL LCD

annunciator and the total weight is displayed for about five seconds and then the

number of samples is displayed for about two seconds.

Advertising