4.7 Filter Setup

Changing the filter settings allows the Dyna-Link to adjust to situations where there is

a lot of movement in the lift or the crane structure. If the reading is not stable, it can

often be improved by increasing the filter setting. Settling time will be longer as the

filter setting is increased. However, the MSI-7300 Dyna-Link 2 employs algorithms

that speed up large tension changes while still controlling vibration even with higher

filter settings.

1) With the 7300 off, press and hold

the

F2

key, then press the

POWER

key.

...or while the 7300 is on, press

F2

and

POWER

simultaneously.

2) The first item of the setup menu

is Func1. Scroll to Filtr with
the

F2

key.

3) To set up the filter, press

F1

. The

display will blink the current filter
setting.

4) Change the filter setting by

pressing the

F2

key.

There are four available filter settings.
Not all choices are shown in this
example.

5) When the desired filter setting is

annunciated, press

F1

. The next

item in the setup menu appears.

6) Either press

ZERO

to exit setup

and store all changes, or
continue to another setup menu
item using the

F2

key.

)YQF

+L

High Filter 1

2))

Blinking

)LOWU

2))

Blinking

/2

Low Filter, Blinking

8QLW

Next Setup Menu Item

Store and return to

weight display

6WRUH

Press Simultaneously

POWER

F2

0

EXIT/SAVE

ZERO

ENTER/SELECT

F1

ENTER/SELECT

F1

SCROLL

F2

SCROLL

F2

SCROLL

F2

SCROLL

F2

F2

SCROLL

0

ZERO

F1

Figure 4-7 Filter Setup Menu