5 auto zero maintenance (azm), Auto zero maintenance (azm), Figure 5-5 – Rice Lake MSI-7300 Dyna-Link 2 User Manual

Page 38: 6hw8s, 6wdqg 2ii, Xwr 6wdqg, 6wruh

Advertising
background image

34 MSI-7300 Operator’s Manual

5.5 Auto Zero Maintenance (AZM)

The Dyna-Link 2 employs an auto zeroing maintenance mechanism to adjust the zero

reading to the center-of-zero (COZ). COZ is defined as the tension reading is within

¼’d’ of zero. AZM continuously adjusts zero to maintain COZ. It is recommended

that AZM is on to maintain the highest accuracy. However, there are circumstances

when it should be turned off. This can happen when minor variations of tension occur

while picking up Dyna-Link attachments and the variations fall within the AZM

capture window. The AZM capture window (usually 1 ‘d’) and capture time (usually

eight seconds) can be adjusted by MSI to meet custom requirements.

1)

With the power on, initiate
calibration by holding down
the

F2

and

ZERO

keys until

the display reads CAL.

The CAL setup menu
appears.

2)

Press

F2

to go the the

SetUP screen.

3)

Press

F1

. The StAnd

menu appears.

4)

Press

F2

to scroll to the

Auto0 screen.

5)

Press

F1

. The AutoZero

mode shows On or OFF.

In this example, we will turn off AZM
(not recommended for typical
operations)

6)

Press

F2

to change to AZM

between on and off.

7)

When the desired mode is
displayed, press

F1

.

8)

The next cal setup menu
item appears.

9)

Press

ZERO

twice to exit

cal setup and store all
changes, or continue to
another cal setup menu
item using the

F2

Key.

&$/

ENTER/SELECT

F1

F2

SCROLL

6HW8S

SCROLL

F2

ENTER/SELECT

F1

0

EXIT/SAVE

ZERO

6WDQG

2II

blinking

Press

Simultaneously

F2

0

ZERO

F1

ENTER/SELECT

F1

2Q

blinking

F2

SCROLL

$XWR

6WDQG

Next Cal Setup Menu Item

0

EXIT/SAVE

ZERO

&$/

Next Cal Menu Item

6WRUH

Changes saved to

Backup Memory

Figure 5-5 Auto Zero Maintenance Setup

Advertising