9 hi-res, 10 print, Hi-res – Rice Lake MSI-7300 Dyna-Link 2 User Manual

Page 21

Advertising
background image

User Key Functions (F1and F2) 17

3.9

HI-RES

Set a function key (

Fx

) to

Hi-Res

, see Section 4.0.

Press the

Fx

key programmed to display the high resolution mode (see Table 1-2 on

page 8). The display will stay in high resolution mode until the selected

Fx

key is

pressed again, or power is cycled. While in the hi-res mode the appropriate

Fx

LED

will blink continuously at a slow rate.
Hi-res mode does not increase the accuracy, but allows for smaller weight increments

to be displayed.
Use Tare or the

ZERO

key to zero out any initial error. Hi-res mode will make the

Dyna-Link 2 more sensitive to motion and movement resulting in a less stable display.

When hi-res is on, the filter is automatically set to the Hi-1 setting (if Hi-2 is already

set, then the filter is not changed). This will have a small effect on settling time. When

hi-res is turned off, the filter setting resets to the previous filter setting.

3.10 PRINT

Set a function key (

Fx

) to

Print

, see Section 4.0.

Pressing the

Fx

key outputs a configured text string to the RS-232 port on the base of

the unit.
If an F-Key is programmed as print and the print setup is configured as continuous,

then the

Fx

key is used for start print/stop print. See Section 6.2 for more details on

data output.
The print function is always available on the optional RF remote display, so it is not

necessary to program an F-Key to “print” if you intend to trigger print outputs from

the remote.
However, if you program F1 or F2 to “print” then pushing F1 or F2 on the Dyna-Link

will cause the comm port on the remote to output the selected data string.
If the RF remote display option is installed, the Dyna-Link cannot use its built in

comm port except for hard-wire connections to the RF remote display or firmware

updates.