2q2ii 2q 3ulqw, Vflg u), Rf setup procedure – Rice Lake MSI-7300 Dyna-Link 2 User Manual

Page 47

Advertising
background image

2Q2II

2Q

3ULQW

RF Setup Procedure

VFLG

U)



example SCID Value







blinking

blinking

Error Correction: If you input a wrong value, press

ZERO

to step

back one digit and reenter.

&KQ/



blinking

1) With the power on, open the

COMM setup menu by
pressing the

F1

and

F2

keys

simultaneously.

The COMM setup menu

choice is Print.

2) Press

F2

to scroll to the RF

setup menus.

3) Press

F1

to enter the RF

setup menu.

4) The display reads OnOff

by pressing

F1

. If it is off,

use the

F2

key to change it

to on. Then push

F1

.

Off is only used when the 8000 is
hardwired to a Dyna-Link.

5) Press

F1

. Next the Scid

(ScaleCore ID) screen is
shown

6) Press

F1

. The current SCID

number is shown.

If the offered SCID value is correct,
push

F1

and jump to step 10.

In this example we’ll enter 3 as an SCID
number. Any value from 1-254 is
acceptable. However, MSI
recommends a value from 20 – 30.

7) To input the SCID value,

press

F2

to start the number

entry process.

8) Use

F2

to change the

number, and

F1

to enter

the number. Add the next
digit by pushing

F2

and

scrolling as required.
Repeat this sequence
until the entire SCID
number is entered.

9) Once the entire SCID

value is entered, press

F1

10) The next RF setup

parameter is “ChnL”
(Channel). Press

F1

to start

the number entry process.

11) The current RF channel

number is displayed.

If the offered RF Channel value is
correct, push

F1

and jump to step 14.

SCROLL

F2

ENTER/SELECT

F1

ENTER/SELECT

F1

ENTER/SELECT

F1

ENTER/SELECT

F1

F2

F2

SCROLL

F2

ENTER/SELECT

F1

ENTER/SELECT

F1

Press Simultaneously

F1

F2

Communication Setup 43

Figure 6-7 RF Setup Procedure

Advertising