1 standard print strings, Gross, Tare – Rice Lake MSI-7300 Dyna-Link 2 User Manual

Page 42: T-cnt

Advertising
background image

38 MSI-7300 Operator’s Manual

6.2.1

Standard Print Strings

1

Current
Tension

Fixed output length: 16. Leading zeros suppressed except for the
LSD.

TTTTTTT

sp

UU

sp

MMMMM

crlf

TTTTTTT – tension data with -sign if necessary.
UU – units
MMMMM – tension mode which for “1” is either NET or GROSS

2

Net Tension

Fixed output length:16. Leading zeros suppressed except for the
LSD.

TTTTTTT

sp

UU

sp

NET

spspcrlf

3

Gross
Tension

Fixed output length: 16. Leading zeros suppressed except for the
LSD.

TTTTTTT

sp

UU

sp

GROSS

crlf

4

Tare Weight

Fixed output length:16. Leading zeros suppressed except for the
LSD.

TTTTTTT

sp

UU

sp

TARE

crlf

5

Total
Weight

Fixed output length: 16. Leading zeros suppressed except for the
LSD.

TTTTTTTTT

sp

UU

sp

TTL

crlf

6

Number of
Samples
Totaled

Fixed output length: 16. Leading zeros suppressed except for the
LSD.

spspspspspsp

SSSSSSS

sp

T-CNT

spcrlf

7

Current
Weight
Mode

Net, Gross, Peak, etc

sp

MMMMM

crlf

8/9

Carriage
Return/

Line Feed

Used to add a space between print records.
crlf

Table 6-1. Standard Print Strings

In the string number entry screen, you can enter combinations of the standard print

strings. For example, to get a NET GROSS TARE printout with a space between

records, simply enter “2349.”
Using SCCMP application (ScaleCore configuration management program), custom

output strings are possible. See the ScCMP programming guide for details.

Note

ScCMP programming can be found on the CD included with the
product or can be downloaded from the MSI website.

The serial output is configured as 9600 baud, Xon/Xoff handshaking, no hardware

handshaking, 1 stop bit, no parity. Other baud rates are possible by special order only.

Advertising