Rice Lake MSI-7300 Dyna-Link 2 User Manual

Page 51

Advertising
background image

Appendix 47

Display toggles between
“Error” and “buttn”

A key is stuck or is being
held down

Check switches for damage

Ensure that a remote is not
continuously transmitting

Optional RF Remote
display does not work

Units not mated

See “Setting the Transmitter
and Receiver Address”
procedures.

Lo Batt is blinking

Battery is low

Replace (alkaline) or recharge
batteries

Unit turns on, then
immediately off

Battery is low

Replace (alkaline) or recharge
batteries

Tension will not zero

System not stable

Wait for stable symbol to turn
on

Increase filtering for more
stability

Zero out of range

Zero range might be limited.
Reduce the tension or use tare
instead

Tension will not tare or
total

System is not stable

Wait for stable symbol to turn
on, or if in a mechanically noisy
crane, increase the filtering or
reduce the size of the Dyna-
Link increment “d.” It is also
possible to increase the motion
window. Contact MSI if you
have a problem getting the
MSI-7300 to zero, tare, or total
due to stability issues.

Setpoint lights blink

Setpoint is enabled and the
trigger point has been
reached

Disable setpoints if they are not
needed

Manual total does not
work

A function key is not set to
“Total”

Set up Func1 or Func2 for
“Total”

Tension must be stable

Increase filtering for more
stability

Auto total does not work

Tension must be stable

Wait for stable symbol to turn
on, or increase filtering for more
stability

Tension thresholds not
reached

You must exceed 1% of
capacity for autototal to work.
Then you must drop below
0.5% of capacity for additional
weighments to register.

Problem

Possible Cause

Solution

Table 7-1. Troubleshooting