6wuq, U) 6wruh, Figure 6-3 print output setup (continued) – Rice Lake MSI-7300 Dyna-Link 2 User Manual

Page 44

Advertising
background image

12) Press

F1

to enter the print rate

number entry screen. The current
print rate appears on the LCD.

In this example, we’ll set the print rate
to an output rate of once every two
seconds.

13) Press

F2

to change the print rate.

Use F2 to scroll the number,
enter each number with the F1
key.

14) When the entire number is

displayed, press

F1

again to

finalize the seconds entry. The
next print menu Item appears,
String.

15) Exit the print setup menu by

pressing

ZERO

twice. The

message

Store

appears briefly

then normal link operation starts.

ENTER/SELECT

F1



blinking

Example Value



blinking

SCROLL

F2



blinking



fixed

ENTER/SELECT

F1

SCROLL

F2

ENTER/SELECT

F1

6WUQ

0

EXIT/SAVE

ZERO

0

EXIT/SAVE

ZERO

U)

6WRUH

The number represents the print
interval rate in seconds. Use 0 for the
fastest the Dyna-Link can go (~5
times per second). To set a once a
minute transmission, set the rate to

60. To set once per hour, set the rate to 3600, etc. Largest
possible entry is 65535 which is >18 hours.

40 MSI-7300 Operator’s Manual

Figure 6-3 Print Output Setup (continued)

Advertising