6 service counters, Service counters, Qw  2/&qw – Rice Lake MSI-7300 Dyna-Link 2 User Manual

Page 39: Figure 5-6 access the service counters warning, Msi-7300

Advertising
background image

Calibration 35

5.6 Service Counters

The MSI-7300 maintains two service counters for safety.

• The first counter counts the number of times the scale has been overloaded.

• The second counter counts lifts above 25% of capacity.

These counters serve to warn the user to inspect the load train after a number of

overloads, also when there is a chance of fatigue failure. The power up routine will be

interrupted when the lift counter exceeds 16383 lifts or the overload counter exceeds

1023 overloads. If the screen displays LFCnt when unit is powered on :

1. Push TARE to display the 25% lift counter.

2. Push TARE again to see the overload lift counter.
3. Push the ZERO key to acknowledge the warning and return to standard scale

operation.

Note

The power up warning message won't appear again for another 16383
lifts ( or 1023 overloads).

1)

Program a user function key to

be TEST (see function key setup)
F o r t h i s e x a m p l e ,

F 1

i s

programmed as TEST.

2)

Press

F1- TEST

.

3)

Within two seconds of pressing the

F1– TEST

key, press

F1

again

(must be F1 regardless of which key is

programmed as TEST).

The test will sequence through steps 4

to 7 automatically unless you stop it by

pressing

F2

immediately, then using

F1

and

F2

each parameter can be

observed statically.

4)

The display flashes LFCnt (for

lift counter) followed by the
number of times the weight has
exceeded 25% of capacity.

5)

Next, the display flashes OLCnt

(for overload counter) followed
by the number of times the
weight has exceeded capacity.

6)

Next,the display flashes the C-

Cal value.

7)

The Dyna-Link returns to

standard weighing mode. If you
interrupted the auto sequence,
press

ZERO

to return to tension

link mode.

/)&QW 

2/&QW

Return to standard weight display



ENTER/SELECT

F1

Number of Lifts above 25% of Capacity



Number of Lifts that exceeded Capacity

example value

example value

Start of Test Sequence

All segments on

&&D/

blinking

blinking

example C-Cal value

Fx

Figure 5-6 Access the Service Counters

WARNING

Only a MSI factory representative can reset the service counters,
as these are important safety warning features. Depending on
the circumstances, a thorough load train inspection might be
necessary to ensure user safety.

Reference MSI’s “Crane Scale Safety and Periodic Maintenance manual” (Pub.
243-08-94D) for proper loading techniques to improve the safety and longevity of
your

MSI-7300

crane scale. This publication is available at www.msiscales.com

and is included in the CD shipped with your crane scale.