Display Window

When a digital weight indicator is connected to a serial port on the computer, TransAct reads the weight
provided by the scale and displays it in the display window. The scale unit of measure (lb-pound or
kg-kilogram) also appears in the display window. To setup TransAct to read a scale stream, select

Admin

| Preferences | Scale Port1

. For more information, refer to

Preferences

in the

Admin

section of this

manual.

To setup a second scale, select

Admin | Preferences | Scale Port 2

. A display window for each scale is

present and both scales will display scale activity. However, only one scale can be active for use at a
time. To activate a scale, click anywhere within the indicator window or use the

Alt+S

keystroke

command to alternate active scales. The weight in the active indicator is displayed in red and a lower
case

‘a’

appears in the bottom right corner.

In the following example,

Scale Port1

is configured for the scale indicator and

Scale Port2

is set to

Manual

. To enter a weight manually, activate the second scale display, and enter weights manually into

the

Weight In/Weight Out

boxes of the

Transaction Detail

form.

Figure 69. Dual Scale Indicators

When the scale port is in

SIM

mode, arrows for increasing and decreasing a truck weight appear next

to the display window. These buttons increase or decrease simulated truck weights in increments of
3000 pounds. The demo version of the software works only in SIM mode.

A red dot in the upper left corner of the display window informs the operator the scale is in motion.
Weight information cannot be stored until the motion indicator has cleared.

To lock the scale weight once the motion indicator has cleared, use the mouse and double click in the
lower left corner of the display window. The truck can drive off the scale and the display will continue
to show the weight. This allows the scale operator to modify transaction details before storing the ticket.

When TransAct has lost communications with the scale, the letter

‘R’

will appear in the upper right

corner of the display window. This indicates TransAct is attempting to re-establish communications
with the scale. If TransAct is unable to re-establish communications, the text “

No Com

” is displayed

and an error message appears.