Jog gate did not close alarm jog count alarm, Jog gate did not close alarm, Jog 1 display – Hardy HI 3010 Filler/Dispenser Controller User Manual

Page 109: Jog display/jog 1 2.0 seconds fi, Jog paused 1.0 second into the jog sequence - 93, Jog count alarm

Advertising
background image

93

CHAPTER 7
Troubleshooting

2.

The Jog sequence resumes from
where the Jog left off when it was
paused.

Jog Gate Did Not Close Alarm

- - - - - ALARM CONDITION - - - - -

You might experience a JOG GATE DID
NOT CLOSE ALARM! also. If the JOG
gate does not close the alarm appears. (See
Fig. 7-37)

FIG. 7-37 JOG GATE DID NOT CLOSE ALARM

1.

Check to see why the gate did not
close. Correct the problem. Press on
the Clear button to clear the alarm.

2.

The Jog sequence resumes from
where the Jog left off when it was
paused. (See Fig. 7-38)

3.

The Filler/Dispenser goes through one
JOG sequence that was previously set
up. (See Fig. 7-38 & 7-39)

FIG. 7-38 JOG 1 DISPLAY

FIG. 7-39 JOG DISPLAY/JOG 1 2.0 SECONDS

4.

The instrument continuously checks
to see if the gain in weight is within
the target window. If it is the fill pro-
cess continues to another procedure.
(See Fig.7-40)

FIG. 7-40 JOG DISPLAY/COMPLETED ONE JOG

SEQUENCE CHECKING WEIGHT

5.

You can pause the JOG cycle by push-
ing the Stop button once at any time
during the JOG cycle. The JOG Hold
display appears. (See Fig. 7-41)

FIG. 3-41 JOG PAUSED 1.0 SECOND INTO THE JOG

SEQUENCE

6.

If the gain in weight is still NOT
within the target window, the instru-
ment automatically continues through
the preset JOG sequences until the tar-
get window is reached and then con-
tinues on to another procedure.

Jog Count Alarm

- - - - - ALARM CONDITION - - - - -

If the JOG sequences are completed and
an UNDERFILL condition still exists, a
JOG count alarm appears telling you that
you have used up the JOGs for this
sequence. (See Fig. 7-42)

FIG. 7-42 JOG COUNT ALARM

1.

Press the Clear button to clear the
alarm.