Output relay #1 address ho0.0, Configuration - mapping setup 2 – Hardy HI 3010 Filler/Dispenser Controller User Manual
Page 83
67
CHAPTER 6
Mapping
down to see it. In our example we selected Output
Relay #1 which has an address of: HO0.0. An equal
“=” sign also appears.
FIG. 6-5 OUTPUT RELAY #1 ADDRESS HO0.0
Step 8. You have now selected the Destination.
Step 9. Click on the Jump to Sources Page button to select
the Source you want for this destination. (See Fig.
6-5) The Configuration, Mapping Setup 2 page
appears. (See Fig. 6-6)
FIG. 6-6 CONFIGURATION - MAPPING SETUP 2
Step 10. Let’s take a moment to look at this page.
•
Local Inputs include the 5 input contact
closures provided by the HI 3010.
•
Control includes the following which is
only a partial list:
1.
Slow Fill
2.
Fast Fill
3.
Refill
4.
Discharge
•
Instrument Setup includes parameters for
setting up the instrument itself and
includes the following which is only a par-
tial list:
1.
Zero Tolerance
2.
Auto Zero Tolerance
3.
Waversaver
4.
Tare Limit Value
•
Ingredient Setup include parameters for
setting up the ingredients to fill or dis-
charge, and includes the following which
is only a partial list:
1.
Auto Preact On
2.
Fills
3.
Fill Time
4.
Slow Gate Time
•
Alarms includes all the alarms for filling
and discharging and includes the following
which is only a partial list:
1.
Motion
2.
Lost OK to Fill
3.
ADC Error
4.
Lost OK to Dispense
•
Network includes the network outputs and
inputs for Hardy Control Link, Control-
Net, DeviceNet, Profibus etc. which is
only a partial list.
1.
Hardy Control-Link Short In
2.
Hardy Control-Link Int Out
3.
DeviceNet Text Out
4.
DeviceNet Int In
•
Process Data includes data parameters
such as the following:
1.
Gross Weight
2.
Net Weight
3.
Totalizer Total Weight
4.
Totalizer Cycles Weight
•
Calibration includes calibration parame-
ters:
1.
Zero Weight
2.
Span Weight
3.
Calibration Type
•
Scratchpad which are empty registers you
can do whatever you want with.
NOTE:
The lists above do not include all the parameters.
For a list of all the parameters and their
addresses please see Appendix A.
Step 11. Back to our example. We want to select Fast Fill
which is a control parameter. Click on the Control
pull down menu. (See Fig. 6-7)