Discharge alarms, Jog display/jog again, Not ok to discharge alarm – Hardy HI 3010 Filler/Dispenser Controller User Manual

Page 110: Discharge gate did not open alarm, Clogged discharge gate alarm

Advertising
background image

HI-3010 Filler/Dispenser/IBC

94

Service Manual

2.

The JOG display reappears asking
you if you want to start the JOG
sequence again. (See Fig. 7-43)

FIG. 7-43 JOG DISPLAY/JOG AGAIN

3.

If you want the instrument to JOG
again, press the Start button to repeat
the JOG sequence.

4.

If you DO NOT want the instrument
to JOG again, press the Stop button.
The instrument goes to the Fill ON
menu if there are more cycles to com-
plete or the Standby Menu if the JOG
was on the last cycle.

Discharge Alarms

Not OK to Discharge Alarm

- - - - - ALARM CONDITION - - - - -

If the instrument determines that it is NOT
OK to Discharge, a Not OK to discharge
alarm appears. (See Fig. 7-44)

FIG. 7-44 NOT OK TO DISCHARGE ALARM

1.

Check to see what is causing the Not
OK to discharge alarm to appear.

2.

Correct the problem.

3.

Press the Clear button to clear the
alarm. The Awaiting Command to
Discharge display appears.

Discharge Gate Did Not Open Alarm

- - - - - ALARM CONDITION - - - - -

If the instrument determines that the dis-
charge gate did not open, the DIS-
CHARGE GATE DID NOT OPEN alarm
appears. (See Fig. 7-45)

FIG. 7-45 DISCHARGE GATE DID NOT OPEN

ALARM

1.

Check to see what is preventing the
discharge gate from opening.

2.

Correct the problem.

3.

Press the Clear button to clear the
alarm. The Awaiting Command to
Discharge display appears.

Clogged Gate Alarm

- - - - - ALARM CONDITION - - - - -

If during the discharge the discharge gate
becomes clogged, and the Auxiliary is
turned OFF, the CLOGGED GATE
ALARM appears. (See Fig. 7-46)

FIG. 7-46 CLOGGED DISCHARGE GATE ALARM

If the Auxiliary is turned ON, the clogged
gate alarm appears if the auxiliary time
elapses and the discharge weight equals
zero, within the zero tolerance setting. The
CLOGGED GATE ALARM appears. (See
Fig. 7-46)

Step 1. When the discharge is complete, the instrument

closes the discharge gate and returns to the Fill On
display or the Standby Display depending on the
filling cycle.

Discharge Gate Did Not Close Alarm

- - - - - ALARM CONDITION - - - - -

If the Discharge gate does not close, a
DISCHARGE GATE DID NOT CLOSE
ALARM appears. (See Fig. 7-47)