HI-3010 Weight Controller

136

Service Manual

HO3.6 = Send Custom Email 6
HO3.7 = Send Custom Email 7
HO3.8 = Send Custom Email 8
HO3.9 = Send Custom Email 9
HSO - Hardy Short Output table. A table of 16-bit integers.

NOTE:

HSO is a distinct table, and does not refer to HO
in any way.

HSO0 = Cycles Ordered for Active Ingredient, 0=continuous
HSO1 = Ingr. 1 Speed. 0=single, 1=dual
HSO2 = Ingr. 2 Speed
HSO12 = Ingr. 12 Speed
HSO13 = Ingr. 1 Fills or Dispenses
HSO24 = Ingr. 12 Fills or Dispenses
HSO25 = Ingr. 1 Auto Preact On. 0=no, 1=yes
HSO36 = Ingr. 12 Auto Preact On
HSO37 = Ingr. 1 Tolerance Selection, 0=weight 1=percent
HSO48 = Ingr. 12 Tolerance Selection
HSO49 = Ingr. 1 Jog Count (max permitted jogs)
HSO60 = Ingr. 12 Jog Count
HSO61 = Ingr. 1 Fill or Dispense Time (s) (max allowed
time for operation)
HSO72 = Ingr. 12 Fill or Dispense Time (s)
HSO73 = Ingr. 1 Auto Fast On. 0=no, 1=yes (automatic
adjustment of fast wt for dual-speed units)
HSO84 = Ingr. 12 Auto Fast On
HSO85 = Ingr. 1 Fast Gate Time (s). (max time for fast gate
proof sw to verify gate operation)
HSO96 = Ingr. 12 Fast Gate Time (s)
HSO97 = Ingr. 1 Fast Proof Switch On. (0=don't use fast
gate proof sw, 1=use proof sw)
HSO108 = Ingr. 12 Fast Proof Switch On.
HSO109 = Ingr. 1 Slow Proof Switch On. (0=don't use slow
gate proof sw, 1=use proof sw)
HSO120 = Ingr. 12 Slow Proof Switch On.
HSO121 = Ingr. 1 Slow Gate Time (s). (max time for slow
gate proof sw to verify gate operation)
HSO132 = Ingr. 12 Slow Gate Time (s).
HSO133 = OK-to-Fill/OK-to-Dispense timer (s). (max time
to wait for OK-to-Fill signal)
HSO134 = Totalizer On. (0=no, 1=yes.)
HSO135 = Auto Print On. (0=no, 1=yes.)
HSO136 = OK-to-Fill Input. (0=don't wait for OK-to-Fill,
1=do wait for it.)
HSO137 = Discharge Enable. (0=don't enter discharge
sequence, 1=enter discharge sequence)
HSO138 = AutoDischarge Enable. (0=wait for Discharge
command, 1=discharge without waiting for command)
HSO139 = OK-to-Discharge Enabled. (0=don't wait for OK-
to-Discharge input, 1=wait for it)
HSO140 = Auxiliary Device time (s). (max time allowed for
Auxiliary Device operation)
HSO141 = Discharge Proof On. (0=don't wait for Discharge
Proof Sw., 1=wait for it)
HSO142 = Discharge Gate Timer (s). (max time for dis-
charge proof sw to verify gate operation)

HSO143 = Use Auto Zero. (0=don't auto zero, 1=auto zero
when within autozero range of zero)
HSO144 = Refill On. (0=do not attempt refill, 1=refill when
needed)
HSO145 = Initial Refill On. (0=do not attempt refill, 1=refill
before operation)
HSO146 = Active Ingredient Number. (1=ingr 1, 2=ingr 2,
12=ingr 12)
HSO147 = WAVERSAVER setting. (0=Off, 1=7.5Hz,
2=3.5Hz, 3=1.0Hz, 4=0.5Hz, 5=0.25Hz)
HSO148 = Calibration Type. (0=Traditional, 1=C2, -1=not
calibrated)

HFI - Hardy Float Input Table

HFI0 = Gross Weight lb
HFI1 = Net Weight lb
HFI2 = Gross Weight
HFI3 = Net Weight
HFI4 = Tare Weight lb
HFI5 = weight Fraction 1 (with =SD board, fraction of wt
currently on input 1)
HFI6 = weight Fraction 2 (with =SD board, fraction of wt
currently on input 2)
HFI7 = weight Fraction 3 (with =SD board, fraction of wt
currently on input 3)
HFI8 = weight Fraction 4 (with =SD board, fraction of wt
currently on input 4)
HFI9 = capacity

HFO - Hardy Float Output Table

HFO0 - user-defined floating point variable, saved in non-
volatile RAM
HFO1 - user-defined floating point variable, saved in non-
volatile RAM
HFO2 - user-defined floating point variable, saved in non-
volatile RAM
HFO3 - user-defined floating point variable, saved in non-
volatile RAM
HFO4 - user-defined floating point variable, saved in non-
volatile RAM
HFO5 - user-defined floating point variable, saved in non-
volatile RAM
HFO6 - user-defined floating point variable, saved in non-
volatile RAM
HFO7 - user-defined floating point variable, saved in non-
volatile RAM
HFO8 - Active Target Weight
HFO9 - Ingr.1 Target Wt
HFO10 - Ingr.2 Target Wt
HFO20 - Ingr.12 Target Wt
HFO21 - Ingr.1 Preact Wt
HFO32 - Ingr.12 Preact Wt
HFO33 - Ingr.1 Max Wt (Tolerance in wt, above target wt)
HFO44 - Ingr.12 Max Wt
HFO45 - Ingr.1 Min Wt (Tolerance in wt, below target wt)