Fill/dispense time parameter, About fill/dispense timer, Wait timer parameter – Hardy HI 3010 Filler/Dispenser Controller User Manual

Page 44: About wait timer, Adjust ingredient 1/jog, Jog menu/default settings, Jog count parameter, Jog off time parameter, Fill timer parameter

Advertising
background image

HI-3010 Filler/Dispenser/IBC

28

Service Manual

PARAMETER:JOG OFF TIME
RANGE: 00.0-99.9
DEFAULT: 1.00

FIG. 4-27 ADJUST INGREDIENT 1/JOG

Step 1. Press the Enter button. The Jog Menu appears with

the cursor in front of Jog On Time. (See Fig. 4-28)

FIG. 4-28 JOG MENU/DEFAULT SETTINGS

Step 2. Press the Clear button to clear the previous entry.
Step 3. Use the alphanumeric key pad to enter the new Jog

On time. In our example we use 1.00 second.

Step 4. Press the Enter button to set the entry.
Step 5. Press the down arrow to move the cursor in front of

Jog Count. (See Fig. 4-29)

FIG. 4-29 JOG COUNT PARAMETER

Step 6. Press the Clear button to clear the previous entry.
Step 7. Use the right or left arrow button to increase or

decrease the Jog Count value.

Step 8. Press the Enter button to set the entry.
Step 9. Press the down arrow button to move the cursor in

front of Jog Off Time. (See Fig. 4-30)

FIG. 4-30 JOG OFF TIME PARAMETER

Step 10. Press the Clear button to clear the previous entry.
Step 11. Use the alphanumeric key pad to enter the new Jog

Off time. In our example we used 1.00 second.

Step 12. Press the Enter button to set the entry.
Step 13. Press the Exit button to return to the Adjust Ingredi-

ent 1 Menu.

Fill/Dispense Time Parameter

About Fill/Dispense Timer

The Fill/Dispense Timer sets the time limit allowed to com-
plete one cycle. To turn off the timer, set the Timer to 0.

PARAMETER:FILL TIMER
RANGE: 0-999
DEFAULT: 120 SECONDS

Step 1. Press the down arrow button until the cursor is in

front of Fill Timer. (See Fig. 4-31)

FIG. 4-31 FILL TIMER PARAMETER

Step 2. You can press the right or left button to increase or

decrease the Fill time or press the Clear button to
clear the current entry and use the alphanumeric
key pad to enter the new Fill Timer parameter. In
our example we used 120 seconds.

Step 3. Press the Enter button to set the entry.

Wait Timer Parameter

About Wait Timer

The Wait Timer parameter is the time after a fill/dispense
cycle you want the system to wait in order to allow the sys-
tem to settle and calculate the fill/dispense weight to see of
the fill/dispense is within the Target Window before moving

Advertising