Chapter 2, Chapter 2: specifications – Hardy HI 3010 Filler/Dispenser Controller User Manual

Page 23

Advertising
background image

7

CHAPTER 2
Specifications

CHAPTER 2: SPECIFICATIONS

About Chapter 2

Chapter 2 lists the specifications for the HI 3010 Filler/Dis-
penser. Specifications are listed for the standard instrument
and for instruments fitted with optional equipment. The
specifications listed are designed to assist in the installation,
operation and troubleshooting of the instrument. Service per-
sonnel should be familiar with this section before attempting
an installation or repair of the instrument.

Specifications for a Standard Instrument

Update Rate:

55 updates per second

Resolution:

Displayed: 1:985,000 (3 mV/V load cells)

Internal 1:1,048,5761

Excitation Voltage:

5 VDC

Drives up to 8 350 ohm load cells

Averages:

1 to 250 - Sliding, User Selectable in Sin-
gle Unit Increments

Input:

Up to eight (8) 350 ohm Full Wheatstone
Bridge, Strain Gauge Load Sensors/Cells
(5 volt excitation) on one vessel.

Signal Voltage Range ± 0-120mV/V (±
600 mV)

Display:

4 line x 20 character backlit LCD

5 x 7 dot matrix

Display Increments (Graduations):

1,2,5,10,20,50,100,200,500 user selectable

Corresponding weight is dependent on the
decimal point location.

Standard Electronic AC Relays:

Wire Size: 12 AWG Maximum

Maximum Switch Current: .5 Amps

Maximum Switch Power: 120 Watts

Maximum Switch Voltage: .5 Amps @
240 VAC

Single Cycle Surge: 85 Amps (Peak)

Standard Electronic DC Relays:

Wire Size: 12 AWG Maximum

Maximum Switch Current: .5 Amps

Maximum Switch Voltage: .5 Amps @ 60
VDC

Switch Voltage: 5-60 VDC

1 second surge: 5 Amps

Non-Linearity:

0.0015% of Full Scale

WAVERSAVER

®

:

Off

7.5 Hz

3.5 Hz

1.0 Hz

0.5 Hz

0.25 Hz

Calibration Techniques:

C2

®

- Second Generation: Electronic

Traditional - Calibration with test weights

Standard Interfaces:

Ethernet - 10/100 Base T; embedded
server

DeviceNet - Master Scanner

Serial RS 232 - simplex to Printer.

Excitation Monitor:

Current less than 10%

Power and Utility Requirements:

Voltage - Universal Power Supply (50/60 Hz)

120-240 VAC ± 10%

12 - 24 VDC

Frequency

47-63 Hz

Advertising