Instrument Configuration

99

change the current password press the ENTER or RIGHT button and enter the current
password, then simply enter the new password and press the ENTER button to save and exit
this submenu; and return to the top level security menu.

The Configuration Lock Parameters

Configuration Lock Parameter

When the Configuration Lock is enabled, the ability to enter the configuration menu
structure is disabled. If the Configuration Lock is disabled, all parameters except the
security parameters can be read through the front panel. The ability to modify these
parameters however is controlled by the calibration, read only, and keypad lock
parameters.This will stop the use of the keypad, but will not stop the ability to change a
parameter if the correct password is used.

On the Web page, on the security web page, select the Configuration Lock parameter, then
select either Enable or Disable from the drop down list.

On the HI 6500 series instrument display, select the security menu and use the UP or
DOWN button to select the Configuration Lock submenu enter the 4 character
alphanumeric configuration password, then select the Configuration Lock parameter. To
ENABLE the Configuration Lock parameter, press the ENTER button.

Configuration Password Parameter

The Configuration Password is a four alphanumeric character sequence. If the password
sequence is not entered correctly through the front panel display the menu leaves the
Configuration Lock submenu.

On the Web page, select the security menu, the Configuration Password will be displayed
on the security web page. To change the Configuration Password, left click inside the text
field and enter the new 4 character alphanumeric password.

On the HI 6500 series instrument display, select the Security menu and use the UP or
DOWN button to select the Configuration Lock submenu. Enter the current password to
enter the submenu. To change the current password, arrow to "password" menu selection,
enter and use the arrow keys to enter a new password, To change the current password press
the ENTER or RIGHT button and enter the current password, then simply use the arrow
keys to enter the new password and press the ENTER button to save and exit this submenu;
and return to the top level security menu.

The Display Lock Parameters

Display Lock Parameter

The Display Lock disables and blanks the front panel display and disables the keypad. If
the ENTER button is pressed, a password dialog box is shown on the screen. If the correct
password is entered the display is unlocked and operator can view the weight data and use
the MODE button to change the weight between Gross and Net. If the ENTER button is
pressed again the Display Lock parameter is reset to ENABLED and the display blanked.