Printer (over rs-232), Usb memory stick, Printer (over rs-232) usb memory stick – Hardy HI 6500 Series User Manual

Page 63

Advertising
background image

Network Configuration 55

Printer (over RS-232)

The HI 6500 series can transmit Gross, Net, Count, Tare values to a serial printer over RS-
232. The printer Baud rate is user selectable at 600, 1200, 2400, 4800, 9600, or 19200
(default is 9600).

The RS-232 printer pinout is:

A sample wiring connection from the HI 6500 seri3esto the printer port is shown above.
The printer parameters can be configured through the web interface or the display panel.

Step 1. Set the baud rate for the RS232 printer, default is 9600.

Step 2. Set the parity bit, default is EVEN

Step 3. Select what values to transmit over the serial interface to the printer using the

printer mode, default is disabled.

a. Gross Weight
b. Net Weight
c. Tare Weight
d. Unit Count
e. All – Gross, Net, Tare, and Count (if Count enabled) values
f. OFF, Printer disabled.

USB Memory Stick

The HI 6500 series provides an interface to an external USB memory stick that allows

HI 6500 parameters to be saved, restored. or copied to another instrument.

The USB memory stick commands can be activated through the web interface or the
display panel.

To access the USB Menu, from the front keypad, select Configuration > Enter,
Communications > Enter, USB >Enter, UP or DOWN arrow to Save or Restore > Enter.

On the Web page: Configuration; communications; USB; save/restore.

GND

DNC

TR+

TR-

PrtRX

PrtTX

Signal
Ground

DO Not
Connect

RS485 Pins Not Used Printer RX Printer TX