Appendix A: Device Settings

110

TruVision Navigator 5.0 Service Pack 3 User Manual

Feature Support

Notes

Notifications Alarm

Video Loss

Disk Full

Disk Failed

Authentication Lock Up

Device Powered Up

Fan Failed

Abnormal Temperature

To setup a SymSafe or SymDec16 to
send TCP notifications, get the
configuration of the device. Under the
Network menu, go to Network
Notification and make sure each
notification on the page is set to TCP.
Under Notification Setup, make sure the
Alarm Server 1 is set to the IP address
of where the TruVision Navigator Server
services are located (Notification Writer
and Notification Processor). Set the
Alarm port as the same port (TCP
Listener Port) you set on the
Notifications Tab of the TruVision
Navigator Server Properties dialog.
Click Save for the device configuration
changes to be sent to the device.
Restart the TruVision Navigator
Notification Writer and Notification
Processor Services via the Services
dialog in TruVision Navigator.

To setup a SymDec 1 or 4 to send
SMTP notifications, get the configuration
of the device. Under the Alarm menu,
go to Email. Enable each of the
notifications using the radio buttons. Set
the SMTP Server to the IP address of
where the TruVision Navigator Server
services are located (Notification Writer
and Notification Processor). Set the
SMTP port as the same port (Email
Listener Port) you set on the
Notifications Tab of the TruVision
Navigator Server Properties dialog.
Click Save for the device configuration
changes to be sent to the device.
Restart the TruVision Navigator
Notification Writer and Notification
Processor Services via the Services
dialog in TruVision Navigator.