Chapter 3: Operation

38

TruVision Navigator 5.0 Service Pack 3 User Manual

Figure 36: Add Device window (Manually)

Note:

After you click OK, fields highlighted with a red exclamation point indicate rejected

values. Place your mouse pointer over the exclamation points for tips on why your
values were invalid. All fields must be valid to successfully add a device.

• Enter

a

Device Title. Values are alphanumeric.

Select the appropriate Device Type from the drop-down menu.

Based on your device type, you may need to select a Streaming Type. For some
devices, there is only one option for the Streaming Type so it is selected by default.
The Streaming Types are defined as follows:

• TCP - TCP is a reliable stream delivery service that guarantees delivery of a data

stream sent from one host to another without duplication or losing data.

• Reverse

TCP - the application connects to the device and the device streams

video back to the application over the existing connection. This option negates
firewall issues on a WAN and is primarily the best option.

Reverse TCP I-Frame - this connection type is similar to the Reverse TCP
except the device only sends I-Frames. This option is useful in limited bandwidth
environments.

• UDP - the application connects to the device and asks the device to stream video

back to the application on a UDP address and port. For this option, the firewall
needs to be configured to allow the device to stream to the application on that
specific port.