Toa M-9000M2 v.2.00 User Manual

Page 103

Advertising
background image

103

[Control output function setting]

NONE

Control Output Function

• Control output function: LD SCENE

01

Scene Memory Bank Number

• Control input function: VOLUP

IN1
0.5 dB

Input/Output Channel Number
Volume Increasing Level

• Control input function: VOLDOWN

IN1
0.5 dB

Input/Output Channel Number
Volume Decreasing Level

• Control input function: CH ON

IN1

Input/Output Channel Number

• Control output function: CH ON

IN1

Input/Output Channel Number

• Control input function: CH MUTE

IN1
OFF
C-OUT01 (When Interlock output control is ON)

Input/Output Channel Number
Interlock Output Control
Interlock Output Terminal

• Control input function: EMG-MUTE

OFF
C-OUT01 (When Interlock output control is ON)

Input/Output Channel Number
Interlock Output Control

• Control input function: PG DISABLE

OFF
OUT1 (When Paging prohibition is ON)
C-IN01 (When Paging prohibition is ON)

Paging Prohibition
Paging Prohibited Channel
Paging Prohibited Control Input Terminal

[Control input function setting]

NONE

Control Input Function

• Control input function: LOADSCENE

01

Scene Memory Bank Number

Advertising