(C5) Monitor switching control input terminal setting (When the ANC monitor switching is set to ON)

M O N S E L E C T ->

C - I N 0 1

Select the control input terminal to switch the ANC inputs* to be monitored.
Selecting the terminal overwrites the previously set function on it if there is.

Each time the designated terminal is closed, the ANC inputs to be monitored are switched in numerical order
from ANC input 1.

* ANC inputs are the input channels of AN-001T Ambient Noise Sensor Input module. One AN-001T module

has 2 input channels. When 2 AN-001T modules are mounted, the AN-001T's inputs in the slot with smaller
number correspond to ANC Input channels 1 and 2, and another's inputs in another slot to ANC Input
channels 3 and 4.

C-IN01 – 04, CIN01 – 12 when C-001T is used (default: C-IN01)

Setting Range

(C6) Interlock output control setting (When the ANC monitor switching is set to ON)

M O

N S E L S Y N C =

O N

(C8) Interlock output terminal setting
(When the ANC monitor switching is set to ON, and the interlock output control to ON)

A N 1 S Y N C -> C O U T

0 1

(C7) Monitored ANC input channel selection
(When the ANC monitor switching is set to ON, and the interlock output control to ON)

S E L E C T S Y N C ->

A N 1

Perform ON/OFF setting for the function that closes the control output terminal in synchronization with the
control input terminal closure of the set number.

OFF (default), ON

Setting Range

Select the ANC input channel. Each channel for which the monitor function is set to ON can be selected.

ANC 1 – 4 (Only ANC input channels for which the monitor function is ON)

Setting Range

Set the control output terminal which is closed in synchronization with switching to the monitored ANC input
channel.
Assigning the function to this terminal overwrites the previously set function on it if there is.

COUT01 – 04, COUT01 – 12 when C-001T is used (default: COUT01)

Setting Range

(C9) Control input terminal number selection

C - I N

0 1

-> N O N E

C-IN01 – 04 (C-IN01 – 12 when C-001T is used), ZM-IN01 – 12* (default: C-IN01)
* Selectable only when the Remote controller type (

p. 82-C20

) is set to ZM-9001 or ZM-9002.

Setting Range

Set the control input terminal number to be assigned to the control input function.
The screen indications ZM-IN01 – 06 or 01 – 04 correspond to the control buttons of the ZM-9001 or ZM-9002
connected to the 9000M2 Series amplifier's remote volume control terminal 1 (REMT VOL 1). The indications
of ZM-IN with subsequent numbers correspond to ZM-9001's or ZM-9002's control buttons connected to the
remote volume control terminal 2 (REMT VOL 2).
To set a terminal number, refer to

p. 78

for the flow chart of the control input function setting.