Function buttons and indicators on the ZM-9011, ZM-9013, and ZM-9014

The lighting mode of the operation indicator differs depending on the function assigned to the Function button.
When a communication error occurs between these remote control panels and the RC-001T module, the
lighting mode differs from that in the normal state regardless of the function assigned to the button. The
respective lighting modes are as follows.

[When the paging function is assigned to the Function button]
The indicator lights when the paging is activated by pressing the
Function button. In this event, it flashes if paging call cannot be
made because the higher-priority broadcast is in progress, and
switches to steady-on once paging call access is enabled after
the higher-priority broadcast completion.

The indicator goes off when the paging call is completed by
pressing the button again.

[When the cross point ON/OFF function is assigned to the Function button]
The indicator lights when the cross point function is enabled by
pressing the Function button, and goes off when turned OFF by
pressing the button again.

[When the scene recall function is assigned to the Function button]
The indicator lights when the preset scene is recalled by pressing
the Function button, and goes off when switched over to other
scene from other devices.

[When the contact control output function is assigned to the Function button]
The indicator lights when the set contact control output is turned ON by pressing the Function button.
When the button operation is set to momentary type, the output turns on and also the indicator lights as long
as the button is pressed. When the button operation is set to alternate type, the output alternates between ON
and OFF each time the button is pressed and the indicator cycles between ON (lit) and OFF (unlit) as well.

[When a communication error occurs]
The operation indicator goes off.
When the Function button is pressed, the indicator lights briefly,
then goes off.

Lit

• At the time of paging activation
(When no priority broadcast is made)

(When priority broadcast is in progress)

• At the time of paging termination

Flash

Unlit

(When set to ON)

(When set to OFF)

Unlit

Lit

(When the scene is recalled)

(When other scene is recalled from
other devices)

Unlit

Lit

Unlit