P.89-c60), P.89-c61), P.89-c62) – Toa M-9000M2 v.2.00 User Manual

Page 89: P.89-c63), P.89-c64), P.89-c65)

Advertising
background image

89

(When the interlock output control is set to ON)

(C60) Interlock output terminal setting

C - I N 0 1 - C - O

U

T

0 1

(C61)
(When the control input function is set to POWER)

C - I N 0 1 ->

P O W E R

(C62) Paging prohibition setting

C - I N 0 1 -> P G

D I S A B L E

Sets the control input to disable paging.

(C63) Paging prohibited output setting

C I N 0 1 - D I S A B L E->

O U T 1

Sets the output to prohibit paging.
When the control input is closed during paging, paging to the set output channel is interrupted.

This screen is displayed only when the interlock output control setting is set to ON.
Set the control output terminal which is closed in synchronization with the control input of the set number.
Assigning a function to this terminal overwrites the previously set function on it if there is.

C-OUT01 – 04, C-OUT01 – 12 when C-001T is used (default: C-OUT01)
Note: When the interlock output control ON/OFF setting is ON.

Setting Range

[When the function is set to POWER]

Assign the power ON or OFF function to the control input terminal.
Closing the set control input turns the power ON, and then opening it turns the power OFF.
Assigning a function to this terminal overwrites the previously set function on it if there is.

OUT1 - 8

Setting Range

(C64) Control output function setting

C - O U T 0 1 ->

N O N E

(C65)

(When the control output function is set to POWER)

C - O U T 0 1 ->

P O W E R

Select the function assigned to the control output terminal.

NONE (default), POWER (Power ON/OFF remote control), SCENE (Scene memory
recall), CH ON (channel ON)

Setting Range

[When the function is set to POWER]

Provides a Level output when the power is turned on.
Assigning a function to this terminal overwrites the previously set function on it if there is.