Toa M-9000M2 v.2.00 User Manual

Page 48

Advertising
background image

Step 1. Speak into the paging microphone connected to the input

of which trigger is set to VOX.

When the audio signal is detected, the paging call goes
through, decreasing the level of the mixed audio signal
being broadcast at the paging destination.

Step 2. Terminate the paging call.

If the audio signals are not detected for a specified period
of time at the paging input, paging is made to terminate.

Step 1. Press the button on the remote control panel.

The corresponding indicator lights.
The level of the mixed audio signal being broadcast at the
paging destination decreases.

When the selected channel is being used by other paging
with higher priority level, the indicator does not light,
indicating that paging cannot be initiated.

Step 2. Make a paging call.

Step 3. Press the button again to terminate the paging call,

restoring the level of the mixed audio signal to the original
value.

48

[Paging initiation by the ZM-9011, ZM-9012, ZM-9013, or ZM-9014 operation]
When assigning the paging activation function to the button on the remote control panel, pressing the function-
assigned button causes the paging to initiate.

1

Lights

Example: ZM-9011

3

M-9000M2

Power amplifier

[Paging initiation using VOX (voice-operated switch) trigger]
Initiates paging when the paging audio signal is detected. There is no need to prepare a control input
additionally as it starts paging by detecting the presence of audio signal. In this case, special attention should
be paid to audio dropout at the beginning of paging call or unintentional start of paging.
The VOX function is available when the D-001T or D-001R module is used.

Advertising