(C16) Control output terminal function display

C - O U T I N F

0 1

= N

O

N E

(C18) Control output terminal status display
(when all are open)

(C18) Control output terminal status display
(when all are closed)

C O U T = - - - - - - - - - - - -

C O U T = 1 2 3 4 5 6 7 8 9 A B C

(C17) Control output terminal status information

C -

O

U

T S

T

A

T

U

S

When STATUS is selected, current control output terminal statuses are displayed on the screen.

(C19) Remote control input terminal setting

R E M O T E S E T T I N G

Sets functions assigned to the remote control terminals (REMT VOL1 and REMT VOL2).

(C20) Remote controller type setting

R E M O T E

1

-> V O L U M E

Displays the function assigned to the control output terminal.
The screen indications represent the following functions:
• NONE:

No function is assigned.

• POWER:

Power ON

• LD SCENE:

Scene memory recall

• CH ON:

Channel ON

• CH MUTE:

Channel mute

• EMG MUTE: Emergency mute activation (All output channel mute)
• PG OUT:

Paging activation

Status of all control output terminals can be confirmed on the screen, with the terminal Nos. 1 – 12 arranged in
numerical order from left to right.
When closed, the terminal number is indicated by alpha-numerals. Alphabet A represents the terminal number
10, B represents 11, and C represents 12.
An open terminal is indicated by an underscore "_".

Set the type of remote controller connected to the remote control input terminals.
Use the Left and Right shift keys to move the setting items on the screen.

• OFF:

Select this setting when no remote controller is connected.

• VOLUME: Select this setting when a normal variable resistor or variable DC power supply unit is connected.
• ZM-9001: Select this setting when the ZM-9001 is connected. This setting adds 6 control inputs. These

inputs are assigned the functions in the setting screen on

p. 86-C43

.

• ZM-9002: Select this setting when the ZM-9002 is connected. This setting adds 4 control inputs and 1

remote volume control. These inputs are assigned the functions in the setting screens on

p. 86-

C43

.

REMOTE 1, REMOTE 2
OFF (default), VOLUME, ZM-9001, ZM-9002

Setting Range

Remote Volume Terminal Number
Controller type