P.88-c54), P.88-c55), P.88-c56) – Toa M-9000M2 v.2.00 User Manual

Page 88: P.88-c57), P.88-c58), P.88-c59)

Advertising
background image

88

(C55) Input/Output channel number selection

C - I N 0 1 - C H M U T E ->

I N 1

(C56) Interlock output control setting

C - I N 0 1 - SYNC

O F F

(When the interlock output control is set to ON)

(C57) Interlock output terminal setting

C - I N 0 1 - C - O

U

T

0 1

(C54)
(When the control input function is set to CH MUTE)

C - I N 0 1 ->

C H M U T E

[When the function is set to CH MUTE]

Assign the function that mutes the input or output channel to the control input.
Closing the control input terminal mutes the set channel.
Assigning a function to this terminal overwrites the previously set function on it if there is.

Using the Input channel or Output channel selection key, select the channel number to be muted.
One control input can mute one input or output channel.

IN1 – 8, OUT1 – 2, Max. OUT8 when T-001Ts are used (default: IN1)

Setting Range

Perform ON/OFF setting for the function that closes the control output terminal in synchronization with the
control input terminal closure of the set number.

ON, OFF (default)

Setting Range

This screen is displayed only when the interlock output control is set to ON.
Set the control output terminal which is closed in synchronization with the control input of the set number.
Assigning a function to this terminal overwrites the previously set function on it if there is.

C-OUT01 – 04, C-OUT01 – 12 when C-001T is used (default: C-OUT01)
Note: When the interlock output control ON/OFF setting is ON.

Setting Range

(C58)
(When the control input function is set to EMG MUTE)

C - I N 0 1 ->

E N G M U T E

(C59) Interlock output control setting

C - I N 0 1 - SYNC

O F F

[When the function is set to EMG MUTE]

Assign the function that simultaneously mutes all output channels to the control input. Closing the control input
terminal mutes all output channels.
This function is used to mute the output provided from the unit during emergency broadcast operation.
Assigning a function to this terminal overwrites the previously set function on it if there is.

Perform ON/OFF setting for the function that closes the control output terminal in synchronization with the
control input terminal closure of the set number.

ON, OFF (default)

Setting Range