P.86-c40), P.86-c41), P.86-c42) – Toa M-9000M2 v.2.00 User Manual

Page 86: P.86-c43), P.86-c44), P.86-c45), P. 86-c43, P. 86

Advertising
background image

86

(C41) Firmware version indication

F I R M V E R S I O N = 1 .0 0

(C42) Memory initialization

(C42) Memory initialization

I N I T I A L I Z E

O K ?

I N I T I A L I Z E , P R O G R E S S

(C40) Slot number selection and 900 series module classification setting

M O D U L E S L O T

1

= D - 0 0 1 T

Use the Left and Right shift keys to move the setting items on the screen.
For slots equipped with 9000 Series plug-in modules, their module model numbers are automatically
displayed and cannot be changed. For slots equipped with 900 Series input modules, select their model
numbers using the Parameter setting knob.
The settings performed here are merely displayed, and have no effect on the audio input and other settings.
Setting the open slot to NONE extinguishes the indicators of the corresponding Input channel and its
subsequent channels on the front panel. Besides, the channels do not appear on any setting screen.

1 – 8 (default: 1)

OTHERS (default), B-01, B-11, B-21, B-41, E-03, E-04, E-05,
E-06, E-07, L-01, L-11, L-41, M-01, M-03, M-11, M-21, M-41,
M-51, M-61, S-01, S-02, S-04, S-20S, T-01, T-02, T-12, U-01,
U-03, U-11, U-12, U-13, U-14, U-21, U-43, U-61, V-01, ML-11T,
NONE

Setting Range

Slot Number

Module Classification

Displays the firmware version number.

Pressing the Enter key initializes all of the unit's current settings to the factory default setting.

(C43) Control input function setting

C - I N 0 1 ->

N O N E

(C44)
(When the control input function is set to LOADSCENE)

C - I N 0 1 ->

L O A D S C E N E

Sets the functions to be assigned to the control input terminals or control buttons of the ZM-9001 or ZM-9002.

[When the function is set to LOADSCENE]

C-IN01 to 12:

NONE (default), LOADSCENE (Scene memory recall), VOLUP (volume
up), VOLDOWN (volume down), CH ON (channel ON), CH MUTE
(channel mute), EMG-MUTE (Cut-off by Emergency control), POWER
(Power ON/OFF remote control), PG DISABLE (Paging disable)

ZM-IN01 to 12: NONE (default), LOADSCENE, VOLUP, VOLDOWN

Setting Range

Closing the control input terminal recalls the settings saved in a Scene memory bank number.
Assigning a function to the control input terminal or ZM-9001/9002's control button overwrites the previously
set function on it if there is.

(C45) Scene memory bank number selection

C - I N 0 1 - L O A D S C E N E

0 1

Select the bank number to recall.

01 – 32 (default: 01)

Setting Range

Advertising