Error indications, Refer to, P. 132 "error indications – Toa M-9000M2 v.2.00 User Manual

Page 132

Advertising
background image

132

19. ERROR INDICATIONS

Possible cause and Remedy

A module is inserted into a wrong slot.
Check to confirm that each module is inserted into a correct slot, and
correctly reinsert the module inserted into the wrong slot.
(Refer to

p. 107 "MODULE INSTALLATION."

)

There may be overload or excessive signal input.
Check input and output signal levels and gain settings, then adjust
them as necessary. If the indicator remains lit, consult your TOA
dealer.

The unit is heated to a high temperature.
Check that the unit is properly installed.
(Refer to

p. 11 "INSTALLATION PRECAUTIONS."

)

Disconnect the AC cord from the unit, and allow the unit to cool for a
while.
The unit automatically resumes operation when its inner temperature
decreases.
If this happens frequently, contact your TOA dealer.

Module-to-Slot configuration was changed or a module was
damaged.
Perform any of the following operations:
(1) Press the Enter key.

The set parameter in question is reset to the default setting.

(2) Press the Memory key.

The unit continues to start up. After start-up is competed, back up
the set parameters using the supplied software, then confirm the
setting in question to correct.

(3) Press the Escape/Back key.

"MODULE SLOT#No. ERROR" appears indicating the error slot.
Reinsert the correct module into the slot.

A communication error between the unit and module occurred.
Disconnect the AC power supply, then reconnect it.
If the indicator remains lit, this may indicate a unit failure. Consult
your TOA dealer.

A setting error occurs and a part of or entire data are initialized.
The indicator goes off by pressing the arrow key, Input selection key,
or Output selection key.
Reconfirm the set data.

A communication error between the RC-001T Remote and Remote
control panel occurred.
Check the cables and remote control panel's setting.

Error indications

MODULE SLOT#No. ERROR

DC PROTECT (OUTPUT #No.)

THERMAL PROTECT

INITIALIZE MEMORY?

The Fault indicator lights.

The Fault indicator flashes.

The Fault indicator continues to
flash.