Xms-1024p – Luxul XMS-1024P User Manual

Page 280

Advertising
background image

280

XMS-1024P

a: 14203 Minuteman Drive, Suite 201, Draper, UT 84020-1685 | luxul.com | 801-822-5450

LUX-UG-XMS-1024P Vers: 081314

The following entries are displayed on this screen:

Cable Test

Port:

Select the Port for Cable Testing.

Pair:

Displays the Pair Number.

Status:

Displays the Connection Status of the cable connected to the Port. The test
results of the cable include normal, close, open, short, impedance or unknown.

Length:

If the Connection Status returned is normal, this will attempt to display the
Length Range of the Cable.

Error:

If the Connection Status is close, open or impedance this will attempt to
display the Length Range of the bad cable.

Note: The Lengths displayed are the lengths of the pairs in the cable,

not that of the physical cable.

Note: The Length results are an approximation and are not to be

exactly relied upon.

16.3.2 Loopback
The Loopback test function loops the sender and the receiver of the signal and is used
to test whether the Port of the Switch is available as well as to check and analyze the
physical connection status of the Port.

Choose the menu

Maintenance>>Device Diagnostics>>Loopback to load the

following page:

Figure 16-8 Loopback

Advertising